Engineering
.
open

Protection and Control Engineer

Engineering

Make protection work the first time.

Wacol + site

On site for protection commissioning and every energisation.

Full-time, permanent

$150,000 to $185,000 plus 12% super.

Mid to senior, 5 to 10 years

We test depth on two relay platforms and IEC 61850, because a settings error found at energisation costs days.

Make protection work the first time. At Kestrel Power you design schemes, configure relays across SEL, Siemens, GE and Hitachi Energy, engineer IEC 61850 and implement network settings with a 100% match to the register. You write the test sheets the commissioning team runs in a day. $150,000 to $185,000 plus super. Wacol, Brisbane, with site attendance at every energisation.

Purpose
  1. The Protection and Control Engineer designs, configures and proves the protection, control and SCADA systems that keep a substation safe and let it energise. You implement network-issued settings exactly and hold every scheme to the network's requirements. You write tests the commissioning team can run in a day, so protection never becomes the reason an energisation date moves.
Responsibilities
  1. Develop protection philosophies and scheme designs for 11 kV to 132 kV: feeder, line differential, transformer, busbar, breaker fail and auto-reclose.
  2. Produce protection and control schematics, panel layouts, cable schedules and I/O lists.
  3. Configure intelligent electronic devices (SEL, Siemens, GE, Hitachi Energy) and engineer IEC 61850 GOOSE and MMS, including SCL file control.
  4. Implement Network Service Provider settings, verify the relay against the issued file, and maintain a version-controlled settings register.
  5. Write relay test plans and secondary injection test sheets, including end-to-end and trip tests.
  6. Design the SCADA and RTU interface and point lists to network and client specifications.
  7. Design secure engineering access and remote connection controls aligned to the Essential Eight.
  8. Attend site for protection commissioning on every project's first energisation.
  9. Review panel shop drawings and witness panel factory acceptance tests.
  10. Answer site requests for information within 24 hours and record lessons in the design standards library.
Essential criteria
  1. Bachelor of Engineering (Electrical) from an Engineers Australia accredited program.
  2. Five or more years in protection and control design or commissioning for substations at 33 kV and above.
  3. Hands-on configuration of at least two relay platforms from SEL, Siemens, GE or Hitachi Energy.
  4. IEC 61850 engineering with SCL files, including GOOSE configuration and testing.
  5. Working knowledge of AS 2067 protection requirements and Network Service Provider protection standards.
  6. Registered Professional Engineer of Queensland (RPEQ), or eligible and able to register within six months.
  7. White card, Queensland C-class licence, and an ESI worker card or willingness to obtain one within 30 days.
  8. Permanent Australian work rights.
Desirable criteria
  1. Powerlink or Energex protection engineering experience.
  2. EPLAN or AutoCAD Electrical drawing proficiency.
  3. IEC 62443 or substation cyber security experience.
  4. Protection coordination studies in PowerFactory.
  5. Experience on data centre UPS and generator protection interfaces.
First 90 days
  1. Days 1 to 30: complete ESI induction, review the protection philosophy library, audit relay configurations on the first live project.
  2. Days 31 to 60: issue the first scheme design package, stand up the settings register with version control.
  3. Days 61 to 90: write test sheets for a live project, support a factory acceptance test and a site trip test.
Success measures
  1. Zero settings errors found at commissioning; the settings register matches network-issued files 100%.
  2. Test sheets issued at least 10 business days before commissioning starts.
  3. At least 90% of protection design packages accepted by the network at first submission.
Screening questions
  1. Which relay platforms have you configured, and for which scheme types (line differential, busbar, transformer)?
  2. Describe a protection mis-operation or near miss you traced to a settings or wiring error. What was the root cause?
  3. How have you managed IEC 61850 SCL file ownership between multiple vendors?
  4. How do you verify network-issued settings against what is loaded in the relay?
  5. What is your RPEQ status?
Package and conditions
  1. Reports to: Head of Engineering.
  2. Salary band: $150,000 to $185,000 plus 12% superannuation.
  3. Award: Professional Employees Award MA000065, engineering classification Level 3 to Level 4 benchmark; paid above award.
  4. Location and roster: Wacol depot, with site attendance for protection commissioning across South East Queensland and northern New South Wales. Monday to Friday, 38 hours; shutdown weekends by roster during commissioning.
  5. Employment type: Permanent, full-time.
  6. How to apply: use the Apply button to open the Kestrel careers portal, answer the five screening questions and attach your CV and tickets. Questions go to [email protected]. Kestrel Power starts trading on 4 January 2027; start dates are agreed with each successful candidate.
open role

Protection and Control Engineer

reports to
Head of Engineering
location
Wacol + site
type
Full-time, permanent
band
$150k – $185k
super
12% on top
Electrical workers inspecting switchgear panels in a dimly lit workshop.